- List 5OHS & WHS procedures to be followed while working on wiring harness.
- List 5OHS & WHS procedures to be followed while working on wiring harness.
- List 5OHS & WHS procedures to be followed while working on wiring harness.
- List 5OHS & WHS procedures to be followed while working on wiring harness.
- Describe the storage and disposal procedure for hazardous materials and toxic substances as per environmental requirements in about 40 – 70 words.
- What is meant by manufacturer specifications and where can it be located? (in about 30 – 50 words)
- Describe the following types of single wiring harness in about 50 – 70 words each.
- Explain the complex wire looms (in about 30 – 70 words).
- How does the thickness of wire gauge affect an electrical system? (in about 40 – 50 words).
- What is CAN Bus system? List 5 advantages of using a CAN-bus.
- Why is it not recommended to untwist the twisted pair in the CAN Bus wiring during repairs? Give 2 reasons.
- Why should all the wirings be shielded?(40-50 words)
- Identify the type of faults in the below given electrical components
- What are the common causes for the below-given faults in an electrical system? (30- 40 words each)
– Component Damage and Wear
– Component Corrosion
– Water and Moisture Ingress
– Damaged Insulation
– Frayed Wires
– Burnt Wires
– Connector Damage
– Terminal Damage - Describe the visual testing procedures for electrical circuits and components in about 40-60 words.
- Describe the procedure for voltage drop test (in about 60 – 80 words).
- How can be the Electrical resistance tested? (in about 100 – 150 words)
- Explain briefly how electrical terminals can be accessed without damaging connectors and wires in about40 -60 words.
- Explain how the panels and covers are removed from wiring system? (in about 70 – 100 words)
- Describe the procedure for removing and replacing components with wiring looms (in about 80 to 110 words).
- Explain briefly the procedure to remove connector terminal pins in about 50 – 70 words.
- Explain the process of terminal crimping in about 100 – 130 words.
- Describe the procedure for soldering electrical wire connections (in 130 – 170 words).
- Explain the procedure to remove and replace connectors including male and female connectors (in about 120 – 140 words).
- Briefly describe the harness and loom protections in about 50 – 70 words.
- How can you identify the cable size and terminal type with the help of current drawn? (in about 40 – 70 words)
- List 5 post repair testing procedures of wiring harness and looms.